⚡ Fast dispatch from UK stock
💷 Trade accounts available
💬 EV, solar & heating specialists
You have no items in your shopping cart.
My Quotes

Ideal for

  • Outdoor EV charger circuits needing a separate RCD and MCB layout
  • Single-phase charger supplies up to 40A
  • Installations needing cast aluminium IP65 protection
  • Grey-finish charger protection on darker external walls

Works well with

  • Single-phase EV chargers up to 40A
  • Dedicated EV radial circuits
  • Outdoor cable glands and terminations
  • Type 2 surge-protected charger supplies

What the unit is and who it suits

BG SyncEV Grey EV Consumer Unit 40A RCD 40A MCB SPD CFEV5A-01 is a dedicated EV protection enclosure intended for charger circuits rather than general-purpose distribution. It is designed for sites that need a weather-resistant board with the key EV protection devices already fitted, making it easier to build a compliant and tidy charger supply without selecting and assembling separate parts from scratch.

The unit suits single-phase EV charger installations up to 40A where the designer prefers a separate RCD incomer and MCB final-circuit arrangement rather than an RCBO layout. It is especially useful on external walls, parking areas, detached garages and other locations where a durable enclosure and straightforward cable entry options matter.

Protection arrangement and why it matters

BG lists CFEV5A-01 as populated with one 40A 30mA double-pole Type A RCD, one 40A B-curve MCB and one Type 2 SPD. That device arrangement gives the installer separate residual-current and overcurrent protection rather than combining both functions into one RCBO. For some designs that is the preferred approach, either because it matches the installer’s normal method or because it aligns more closely with the way the charger circuit is being laid out and maintained.

The Type A RCD is important in EV charger work because modern charger loads can involve pulsating DC residual currents that a simpler AC-only device is not intended to detect. The dedicated Type 2 SPD also matters because surge protection is now a normal part of sound EV circuit design rather than an optional extra.

Enclosure design and outdoor suitability

BG states that the enclosure is IP65 rated, UV stable and manufactured from 2mm cast aluminium ADC12. The published dimensions are 176 x 233 x 100mm and the enclosure includes built-in padlock provision, wire-seal tabs and multiple M20 knockouts that can be drilled up to M32. Cover blanks are removable and the total format is 5 module, 5 way.

Those details are useful in practice because EV charger protection boards are often installed where wind, rain, dust and direct sunlight are real considerations. A cast aluminium IP65 enclosure is a better answer for that environment than a lighter indoor-only housing. The darker anthracite grey finish can also be easier to place neatly on darker facades and ancillary buildings.

Installation implications and use-case fit

CFEV5A-01 is intended for EV charger protection, so it makes most sense on a dedicated radial supply to a fixed charger or similar EV load arrangement. The B-curve MCB is suited to standard circuit protection scenarios where a dedicated EV radial is being installed in a typical domestic setting. Installers working on single-phase home charger jobs will recognise this as a straightforward configuration when higher inrush tolerance is not specifically required.

Because the enclosure is already populated, it can also help keep site work cleaner. There is less need for device selection and less risk of mixing parts from incompatible board families. That can be valuable on repeat charger work where consistency matters.

Warranty and product confidence

BG’s official EV circuit protection documentation shows a 10-year warranty for this enclosure family. That is a helpful commercial point because it supports the product’s role as a fixed safety component expected to remain in service for the long term rather than a temporary accessory around the charger install.

Why this exact variant may be the right choice

CFEV5A-01 is the right choice where the site wants a grey cast aluminium EV protection board with separate Type A RCD and 40A B-curve MCB protection. It is also the better fit where outdoor or semi-exposed placement makes IP65 protection essential and where a pre-configured board is preferred over assembling separate devices manually.

FAQs

What protection devices are fitted in this unit?

BG lists a 40A 30mA double-pole Type A RCD, a 40A B-curve MCB and a Type 2 SPD.

Is it suitable for outdoor installation?

Yes. BG states IP65 protection and UV-stable cast aluminium construction for indoor or outdoor use.

What colour is the enclosure?

The CFEV5A-01 is anthracite grey, listed as RAL 7016.

Is it designed specifically for EV circuits?

Yes. BG identifies this range as EV circuit protection designed for EV charger applications.

What warranty is supplied?

BG lists a 10-year warranty for this IP65 EV circuit protection enclosure family.

Products specifications

Attribute name Attribute value
Enclosure Rating IP65
Components Included 40A 30mA Type A RCD, 40A Type B MCB, Type 2 SPD
Dimensions 170 x 200 x 100mm
Weight 4.3Kg (excluding wall bracket)
Material Aluminium, Powder Coated
Application Suitable for flat and pitched roofs

Loading delivery information...